A Heidenhain TNC that will not boot is almost always one of four boxes, and the cabinet tells you which one before you open a manual. On a TNC 426 or TNC 430 the whole control is a single LE logic unit. From the iTNC 530 onward it splits into an MC main computer and a CC controller unit. The drive power comes from a separate UV or UVR supply unit with its own LED column, and that column is where you should look first.
What follows is how to tell the generations apart from the labels, what those LEDs mean, and what wears out inside an MC or an LE after fifteen years in a machine cabinet.

Which box is in front of you
| Unit | Belongs to | What it does | What fails first |
|---|---|---|---|
LE 426, LE 430, LE 430M
|
TNC 426, TNC 430 | Main computer, PLC and position control in one enclosure | Hard disk, buffer battery, fan |
MC 320, MC 420, MC 422
|
TNC 320, iTNC 530 | NC kernel, PLC and the mass storage card | CF card, battery, internal supply |
CC 422, CC 424, CC 61xx
|
iTNC 530 and later | Closed-loop speed control, PWM out to the inverter | Rarely the fault, often condemned anyway |
UV, UVR 1xx
|
Modular inverter systems | Rectifies mains to the DC link, feeds 5 V, 15 V and 24 V | DC-link capacitors, fans, input phases |
The trap that catches buyers: an MC 320 (ID 511442-xx) and its successor the MC 321 are not interchangeable. The MC 320 runs on 85 to 264 V AC, the MC 321 needs 24 V DC. The card slot changed to CFast, so NC software 340551-xx will not run on the newer computer and the machine operating panel has to change with it.
Read the supply unit LEDs before you touch the computer
Heidenhain puts a full diagnostic column on the front of the UV and UVR power supply units, and it reports faults that have nothing to do with the unit itself. On the 1xx family, including the UVR 120D 22 kW regenerative supply, the signals that matter are these:
- READY. The supply unit is happy and is telling the MC or CC so.
- POWER FAIL. DC link below 410 V. On a 3AC 400 V machine that means the incoming mains has fallen under roughly 290 V.
- AC FAIL. A phase is missing.
- TEMP. Heat sink above 95 °C.
- Overvoltage. DC link above approximately 800 V. The power modules are switched off.
- Leakage current. Usually a ground fault in a motor winding or a motor cable.
- X71 SPINDLE, X72 AXES. The safety relay for the spindle or for the axes has tripped.
Here is the mistake that gets a supply unit replaced for nothing. POWER FAIL and AC FAIL are both read as "the unit is dead", and both are far more often a problem upstream of it: a blown fuse in one phase, a loose terminal in the isolator, a contactor pole that is no longer making. Measure all three phases at the input terminal before you order anything. And remember the DC link holds its charge after the main switch is off. Give it the discharge time printed on the unit, then confirm with a meter.

What actually wears out inside an MC or an LE
Mass storage. The TNC 426 and TNC 430 boot from an internal 2.5 inch PATA hard disk, and those drives are long past their rated life. A loader message about a hard disk problem on an LE 430M logic unit is a corrupted system partition, and the auto-repair it offers can lose data. Image the drive before you accept anything the loader suggests.
Buffer battery. The message EXCHANGE BUFFER BATTERY is a warning, not a failure, and that is exactly why it gets ignored. The battery backs the RAM holding machine parameters and remanent PLC data. Replace it within days, and take a full backup first. A dying cell also produces parameter faults that read like a disk problem, so check the battery before you blame the drive.
Heat. The TNC monitors the operating temperature of the logic unit and the I²t load of the power modules and motors. Blocked filter mats and a seized cabinet fan will produce a temperature fault on a machine where nothing electrical has changed at all.
Fatal errors. White letters on a black background, typically HEIDENHAIN FATAL ERROR, is the operating system giving up. Axes decelerate at the current limit, the keyboard goes dead, and clearing it takes the END BLOCK key or the main switch followed by re-referencing every axis. Write down the full text before you cycle power. It disappears on restart.
When the control is really blaming the encoder
A large share of calls that start with "the control is faulty" end at a connector. The position inputs on an MC 420 main computer accept 1 Vpp or EnDat, and a signal outside the window is reported as a measuring system error, which looks identical to a failing input board. Check the shield clamp and the plug at the motor, and treat anything in a drag chain as suspect: those cables break internally long before the fault becomes permanent. We keep AE 403 encoder cable assemblies for that reason.
If the encoder itself is finished, the Id.Nr. on the label decides the replacement, not the model name. Stock includes the ERN 1387, Id.Nr. 749144-01 and the AE LS 403C scanning head, Id.Nr. 297 078-30. Our guide to matching an encoder by Id.Nr. walks through the label and the interface guide covers 1 Vpp against EnDat.

Quick answers
How do I tell an LE from an MC at a glance?
Count the boxes. An LE is one enclosure doing everything on a TNC 426 or TNC 430. From the iTNC 530 onward the computing is in an MC and the axis speed control sits in a separate CC alongside it. The label on the front face gives you the family and the Id.Nr.
Can I drop in any MC 420 I find?
No. The variant suffix matters, the NC software and SIK licensing have to match the machine, and on the iTNC 530 only the six control loop version of the CC 422 pairs with an MC 420. The HEIDENHAIN documentation downloads carry the service manual for the exact combination.
The control shows EXCHANGE BUFFER BATTERY. How long have I got?
Days, not months, and the clock is not the point. The risk is that the next power-down loses machine parameters and remanent PLC data. Take a full backup first, then change the cell. That order has saved entire commissioning files.
POWER FAIL is lit on the supply unit. Is the unit scrap?
Probably not. POWER FAIL means the DC link dropped below 410 V, which usually means the mains did too. Check all three incoming phases, the fuses and the contactor before you condemn the module. AC FAIL says the same thing more directly: a phase is missing.
Is a used TNC control unit a sensible replacement?
For this generation it is often the only practical one. Many MC, LE and UV units are long out of production, so the alternatives are a repair with a lead time or a full retrofit. What matters is that the Id.Nr. and its suffix match. Our used parts buying guide covers the checks worth making.
A diagnostic order that works
- Write down the screen text and the full Id.Nr. from every unit in the rack, suffix included.
- Read the LED column on the UV or UVR supply unit before you open anything.
- If POWER FAIL or AC FAIL is lit, measure the three incoming phases and the fuses first.
- Wait out the DC-link discharge time and verify it with a meter.
- Back up the machine parameters and the PLC program before touching a battery or a disk.
- On a measuring system error, check connector, shield and cable before the encoder.
Machine down with a TNC in front of you? Send us the screen text and the Id.Nr. from the unit label and we will tell you what is on the shelf. Browse CNC controls, the Heidenhain range and encoders, or contact us. Parts are inspected and bench-tested where applicable, ship from EU stock, and carry a 30-day functional warranty from the date of delivery.
Related reading on Samonde
- Heidenhain encoder problems and error messages
- Which encoder interface: 1 Vpp, TTL or EnDat
- SIMODRIVE 611 troubleshooting, for LE 430M machines
- SINUMERIK 840D alarm codes
Also on the shelf: a PLD-H position display unit, an ND 523 digital readout, and for LE 430M installations a SIMODRIVE 611 control board.
These controls were built to be serviced, which is why the LEDs and the Id.Nr. system exist at all. Treat the cabinet as a set of parts that each report their own state and most TNC faults stop being mysterious. The ones that remain are usually a cable.
Have the part number from the nameplate? Paste it into our free Heidenhain part number decoder (for example 297078-30): it shows what the part is, how else the number is written and whether we have it in stock.