{"product_id":"entes-mkc-06p-motor-protection-relay-380-400-v","title":"ENTES MKC-06P Motor Protection Relay 380-400 V","description":"\u003cdiv style=\"max-width:880px;color:#0D1B2A;line-height:1.6;\"\u003e\n  \u003cdiv style=\"display:flex;flex-wrap:wrap;gap:8px;margin:0 0 22px;\"\u003e\n    \u003cspan style=\"display:inline-flex;align-items:center;gap:6px;background:#FFF1E6;color:#B5560F;font-size:13px;font-weight:600;padding:7px 13px;border-radius:999px;\"\u003eNew Surplus\u003c\/span\u003e\n    \u003cspan style=\"display:inline-flex;align-items:center;gap:6px;background:#EDF2F7;color:#1B3A5B;font-size:13px;font-weight:600;padding:7px 13px;border-radius:999px;\"\u003e14-30 days depend on the parts\u003c\/span\u003e\n    \u003cspan style=\"display:inline-flex;align-items:center;gap:6px;background:#EDF2F7;color:#1B3A5B;font-size:13px;font-weight:600;padding:7px 13px;border-radius:999px;\"\u003eShip in 24-48 hours with tracking\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003cp style=\"font-size:16px;line-height:1.75;margin:0 0 30px;color:#2A323C;\"\u003eThe ENTES MKC-06P is a three-phase motor protection relay for 380-400 V supplies. Its front panel is marked \"Phase Failure Device (Phase Sequence)\". It monitors phases L1, L2 and L3 for phase failure, wrong phase sequence and phase asymmetry, and switches one changeover output contact (terminals 1-2-3). The trip delay t(s) is adjustable on a dial marked 2 to 10, and the asymmetry threshold on a dial marked 5 to 15 %. Separate terminals accept a PTC thermistor input for motor temperature monitoring. Four front LEDs indicate phase sequence, asymmetry, On and Out. The housing mounts on a DIN rail.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:12px;font-weight:700;letter-spacing:.09em;text-transform:uppercase;color:#E8720C;margin:0 0 12px;\"\u003eSpecifications\u003c\/h3\u003e\n  \u003cdiv style=\"border:1px solid #E6E8EC;border-radius:12px;overflow:hidden;margin:0 0 30px;\"\u003e\n    \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background:#F6F8FA;\"\u003e\n\u003ctd style=\"padding:13px 18px;color:#6B7280;width:42%;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:13px 18px;color:#0D1B2A;font-weight:600;\"\u003eENTES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:13px 18px;color:#6B7280;width:42%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:13px 18px;color:#0D1B2A;font-weight:600;\"\u003eMKC-06P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F6F8FA;\"\u003e\n\u003ctd style=\"padding:13px 18px;color:#6B7280;width:42%;\"\u003eType\u003c\/td\u003e\n\u003ctd style=\"padding:13px 18px;color:#0D1B2A;font-weight:600;\"\u003eThree-phase motor protection relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:13px 18px;color:#6B7280;width:42%;\"\u003eFront panel marking\u003c\/td\u003e\n\u003ctd style=\"padding:13px 18px;color:#0D1B2A;font-weight:600;\"\u003ePhase Failure Device (Phase Sequence)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F6F8FA;\"\u003e\n\u003ctd style=\"padding:13px 18px;color:#6B7280;width:42%;\"\u003eSupply voltage\u003c\/td\u003e\n\u003ctd style=\"padding:13px 18px;color:#0D1B2A;font-weight:600;\"\u003e380-400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:13px 18px;color:#6B7280;width:42%;\"\u003eMonitored phases\u003c\/td\u003e\n\u003ctd style=\"padding:13px 18px;color:#0D1B2A;font-weight:600;\"\u003eL1, L2, L3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F6F8FA;\"\u003e\n\u003ctd style=\"padding:13px 18px;color:#6B7280;width:42%;\"\u003eTime delay\u003c\/td\u003e\n\u003ctd style=\"padding:13px 18px;color:#0D1B2A;font-weight:600;\"\u003eAdjustable t(s), dial marked 2 to 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:13px 18px;color:#6B7280;width:42%;\"\u003ePhase asymmetry\u003c\/td\u003e\n\u003ctd style=\"padding:13px 18px;color:#0D1B2A;font-weight:600;\"\u003eAdjustable, dial marked 5 to 15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F6F8FA;\"\u003e\n\u003ctd style=\"padding:13px 18px;color:#6B7280;width:42%;\"\u003eThermistor input\u003c\/td\u003e\n\u003ctd style=\"padding:13px 18px;color:#0D1B2A;font-weight:600;\"\u003ePTC thermistor terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:13px 18px;color:#6B7280;width:42%;\"\u003eOutput\u003c\/td\u003e\n\u003ctd style=\"padding:13px 18px;color:#0D1B2A;font-weight:600;\"\u003e1 changeover contact, terminals 1-2-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F6F8FA;\"\u003e\n\u003ctd style=\"padding:13px 18px;color:#6B7280;width:42%;\"\u003eIndicators\u003c\/td\u003e\n\u003ctd style=\"padding:13px 18px;color:#0D1B2A;font-weight:600;\"\u003eLEDs: phase sequence, asymmetry, On, Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:13px 18px;color:#6B7280;width:42%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:13px 18px;color:#0D1B2A;font-weight:600;\"\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F6F8FA;\"\u003e\n\u003ctd style=\"padding:13px 18px;color:#6B7280;width:42%;\"\u003eDocumentation\u003c\/td\u003e\n\u003ctd style=\"padding:13px 18px;color:#0D1B2A;font-weight:600;\"\u003eInstruction leaflet in Turkish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:13px 18px;color:#6B7280;width:42%;\"\u003eCondition\u003c\/td\u003e\n\u003ctd style=\"padding:13px 18px;color:#0D1B2A;font-weight:600;\"\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#F6F8FA;\"\u003e\n\u003ctd style=\"padding:13px 18px;color:#6B7280;width:42%;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding:13px 18px;color:#0D1B2A;font-weight:600;\"\u003e14-30 days depend on the parts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003ch3 style=\"font-size:12px;font-weight:700;letter-spacing:.09em;text-transform:uppercase;color:#E8720C;margin:0 0 12px;\"\u003eCondition \u0026amp; testing\u003c\/h3\u003e\n  \u003cdiv style=\"border-left:3px solid #E8720C;background:#FAFBFC;padding:14px 18px;border-radius:0 8px 8px 0;margin:0 0 30px;\"\u003e\n    \u003cp style=\"margin:0;font-size:14px;line-height:1.7;color:#2A323C;\"\u003eNew surplus stock, never used. Some units may have had the box opened, but none were installed or used. Original boxes show some storage marks.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003ch3 style=\"font-size:12px;font-weight:700;letter-spacing:.09em;text-transform:uppercase;color:#E8720C;margin:0 0 12px;\"\u003eCompatibility\u003c\/h3\u003e\n  \u003cp style=\"font-size:14px;line-height:1.7;margin:0 0 30px;color:#2A323C;\"\u003ePlease contact us to confirm compatibility with your configuration.\u003c\/p\u003e\n\n  \u003ch3 style=\"font-size:12px;font-weight:700;letter-spacing:.09em;text-transform:uppercase;color:#E8720C;margin:0 0 12px;\"\u003eWhat's included\u003c\/h3\u003e\n  \u003cp style=\"font-size:14px;line-height:1.7;margin:0 0 30px;color:#2A323C;\"\u003eMKC-06P relay, instruction leaflet (Turkish), original box. Boxes show some storage marks.\u003c\/p\u003e\n\n  \u003cdiv class=\"smd-web-only\" data-web-only=\"true\"\u003e\n  \u003ch3 style=\"font-size:12px;font-weight:700;letter-spacing:.09em;text-transform:uppercase;color:#E8720C;margin:0 0 12px;\"\u003eBefore you order\u003c\/h3\u003e\n  \u003cul style=\"margin:0 0 30px;padding-left:20px;font-size:14px;line-height:1.7;color:#2A323C;\"\u003e\n\u003cli style=\"margin:0 0 8px;\"\u003eConfirm your supply is three-phase 380-400 V; the relay is marked for this range.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 8px;\"\u003eCheck that the single changeover output contact (terminals 1-2-3) suits your contactor or control circuit.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 8px;\"\u003eUse the PTC thermistor terminals only if the motor has PTC sensors fitted.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 8px;\"\u003eThe instruction leaflet is in Turkish.\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n  \u003ch3 style=\"font-size:12px;font-weight:700;letter-spacing:.09em;text-transform:uppercase;color:#E8720C;margin:0 0 12px;\"\u003eCompatible \u0026amp; Related\u003c\/h3\u003e\n  \u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:0 0 30px;\"\u003e\u003ca href=\"https:\/\/www.samonde.com\/collections\/relays-contactors\" style=\"display:inline-flex;align-items:center;gap:7px;text-decoration:none;border:1px solid #D7DBE0;color:#0D1B2A;font-size:14px;font-weight:600;padding:10px 16px;border-radius:8px;\"\u003eMore Protection Relays \u003cspan style=\"color:#E8720C;\"\u003e→\u003c\/span\u003e\u003c\/a\u003e\u003c\/div\u003e\n\n  \n\u003c\/div\u003e","brand":"ENTES","offers":[{"title":"Default Title","offer_id":66211945972061,"sku":"MKC-06P","price":45.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1069\/2821\/0269\/files\/entes-mkc-06p-entes-phase-failure-and-phase-sequence-relay-with-original-box-and-instruction-leaflet-1.jpg?v=1791978003","url":"https:\/\/www.samonde.com\/es\/products\/entes-mkc-06p-motor-protection-relay-380-400-v","provider":"Samonde","version":"1.0","type":"link"}